AT2327 Alarm Dosimeter

Radiation control of:
– radiation-sensitive and radiation-dangerous sites and facilities
– environment
– restricted area beamline at linear accelerators (LINACs) and other pulsed-radiation facilities

  • Flexible and reliable multichannel stationary monitoring system
  • Independent measurements of gamma and neutron radiation dose rates and flux densities of neutron and beta particles
  • Integrated sound and light alarm
  • System health self-check function
  • Software for centralized radiation environment monitoring on a remote terminal
  • Automatic data logging
  • Backup power source
  • Open communication protocols for integration into external security systems

Request a quote

Specification

AT2327 Alarm Dosimeter
Number of detection units in one alarm dosimeter 1 – 10
Number of alarm dosimeters in system configuration with PC connection Up to 32
Maximum distance between a detection unit and the control panel/PC 1000 m
Burn-up life ≥100 Sv
≥108 Sv (BDKG-27)
≥5·104 Sv (UDKG-37/2)
Detector    BDKG-02 / BDKG-17 Geiger-Mueller counter tube
BDKG-204 Scintillation plastic, Ø30×15 mm
BDKG-11 NaI(TI) scintillator, Ø63×63 mm
BDKG-27 Ion chamber
UDKG-37/2 Silicon semiconductor detector +Geiger-Muller counter tube
BDPB-01 Scintillation plastic, 30 cm2
BDKN-02 / BDKN-04 He-3 counter in polyethylene moderator
Measurement range of gamma radiation ambient dose equivalent rate    BDKG-02 0.1 µSv/h – 10 Sv/h
BDKG-204 0.05 µSv/h – 10 Sv/h
BDKG-11 0.03 – 100 µSv/h
BDKG-17 1 mSv/h – 100 Sv/h
BDKG-27 50 mSv/h – 4000 Sv/h
UDKG-37/2 1 µSv/h – 5000 Sv/h
Measurement range of gamma radiation average pulsed radiation dose rate    UDKG-37/2 80 µSv/s – 0.3 Sv/s
(pulse repetition rate is not less than 20 cps,
duration not less than 1 μs)
Measurement range of neutron radiation ambient dose equivalent rate    BDKN-02 0.1 µSv/h – 10 mSv/h [From Pu-Be source]
BDKN-04 0.1 µSv/h – 10 mSv/h
Measurement range of beta particles flux density    BDPB-01 1 – 5·105 particle·min-1·cm-2
Measurement range of neutron flux density    BDKN-02 0.1 – 104 neutron·s-1·cm-2
BDKN-04 0.1 – 104 neutron·s-1·cm-2 [From Pu-Be source]
Energy range of gamma radiation    BDKG-02 60 keV – 3 MeV
BDKG-11 50 keV – 3 MeV
BDKG-17 60 keV – 3 MeV
BDKG-27 60 keV – 1.5 MeV
BDKG-204 20 keV – 10 MeV
UDKG-37/2 50 keV – 10 MeV
Energy range of beta radiation    BDPB-01 155 keV – 3.5 MeV
Energy range of neutron radiation    BDKN-02 / BDKN-04 0.025 eV – 14 MeV
Typical sensitivity to 137Cs gamma radiation    BDKG-02 4.0 cps/(µSv·h-1)
BDKG-204 70.0 cps/(µSv·h-1)
BDKG-11 1970 cps/(µSv·h-1)
BDKG-17 0.005 cps/(µSv·h-1)
BDKG-27 2.1 μC/Sv
UDKG-37/2 0.15 cps/(µSv·h-1), for dose rate ≤0.2 Sv/h;
58 mV/(Sv·h-1), for dose rate >0.2 Sv/h
Typical sensitivity to 90Sr+90Y beta radiation    BDPB-01 0.3 cps/(particle·min-1·cm-2)
Typical sensitivity to Pu-Be neutron radiation    BDKN-02 / BDKN-04 0.5 cps/(neutron·s-1·cm-2)
BDKN-02 / BDKN-04 0.355 cps/(µSv·h-1)
Energy dependence relative to 662 keV (137Cs)    BDKG-02 -20%…+35%
BDKG-11 ±20%
BDKG-17 -25%…+35%
BDKG-27 ±30%
UDKG-37/2 ±30%
BDKG-204 -45% to +35% (20 – 60 keV); ±25% (60 keV – 3 MeV);
±50% (3 – 10 MeV)
Protection class    BDKG-02 IP57
BDKG-11 IP65 (In sealed container)
BDKG-17 IP64
BDKG-27 IP65 (Processing unit); IP65 (Ion chamber)
BDKG-204 IP67
UDKG-37/2 IP68 (Detection unit); IP65 (Interface unit)
BDPB-01 IP64
BDKN-02 IP54
BDKN-04 IP54
Processing Unit IP55
Alarm Unit IP65
Data Display IP21

Design and specifications are subject to change without notice.
For details please refer to the datasheet.

Downloads

You have not viewed any product yet!